Skip to content

BMS_a037 — SW Flood Port Open

Full alert identifier: BMS_a037_SW_Flood_Port_Open

Some fields retain information from an earlier alert reference.

Alert description

The Battery Management System (BMS) has detected that at least one flood port is open.

Potential impact

This alert is primarily informational and used for logging purposes.

Set condition

The BMS detects that voltage of the flood port switch sensor indicates that one or more flood ports is open.

Clear condition

The BMS detects that voltage of the flood port switch sensor indicates that both flood ports are closed.

Signals to check

These diagnostic fields are associated with BMS_a037. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Flood Port 1 State BMS_a037_floodPort1State —
Flood Port 1 Voltage BMS_a037_floodPort1Voltage —
Flood Port 2 State BMS_a037_floodPort2State —
Flood Port 2 Voltage BMS_a037_floodPort2Voltage —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of BMS_a037.