BMS_a058 — SW Bandolier Model Reset
Full alert identifier: BMS_a058_SW_Bandolier_Model_Reset
Some fields retain information from an earlier alert reference.
Alert description
The Bandolier Thermal Model was reset.
Potential impact
This alert is primarily informational and is used for logging purposes. No expected impact on vehicle functionality.
Set condition
The thermal model had invalid input data at wake from sleep, or the model temperature estimate diverged too far from the thermistor measurement.
Clear condition
The thermal model receives valid input data or the model temperature estimate is within the bounds of the thermistor measurement.
Signals to check
These diagnostic fields are associated with BMS_a058. Check the alert's Payload in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Ambient Temp Invalid
BMS_
|
— |
Bando Thm Model State
BMS_
|
— |
Brick Dissipation Invalid
BMS_
|
— |
Flow Rate Invalid
BMS_
|
— |
Inlet Coolant Temp Invalid
BMS_
|
— |
Sanity Check Failed
BMS_
|
— |
Temp Delta 1
BMS_
|
— |
Temp Delta 2
BMS_
|
— |
Show 3 more fields
| Signal | Unit |
|---|---|
Temp Delta 3
BMS_
|
— |
Temp Delta 4
BMS_
|
— |
Thermistor Temps Invalid
BMS_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of BMS_a058.