Skip to content

CP_a073 — Iec Combo Shutdown

Full alert identifier: CP_a073_iecComboShutdown

Some fields retain information from an earlier alert reference.

Alert description

The charge port (CP) electronic control unit (ECU) detects that the Combined Charging System (CCS) charge session was aborted.

Potential impact

CCS charging may not start or may be interrupted.

Set condition

The CP ECU detects the CCS charge session was aborted.

Clear condition

Clears when CCS charging is complete or shut down.

Signals to check

These diagnostic fields are associated with CP_a073. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Bms Shutdown Requested CP_a073_bmsShutdownRequested —
Ccs 1 Adapter Btn Press CP_a073_ccs1AdapterBtnPress —
Ccs Ac State CP_a073_ccsAcState —
Ccs Dc State CP_a073_ccsDcState —
Ccs Energy Type CP_a073_ccsEnergyType —
Ccs Manager State CP_a073_ccsManagerState —
Ccs Shutdown Reason CP_a073_ccsShutdownReason —
Charge Cable Btn Press CP_a073_chargeCableBtnPress —
Show 8 more fields
Signal Unit
Combo Handle Not Present CP_a073_comboHandleNotPresent —
Comms Fault CP_a073_commsFault —
Cp Internal Stop Chg Request CP_a073_cpInternalStopChgRequest —
Emergency Shutdown CP_a073_emergencyShutdown —
Evse Emergency Shutdown Requested CP_a073_evseEmergencyShutdownRequested —
Evse Shutdown Requested CP_a073_evseShutdownRequested —
Services Not Supported CP_a073_servicesNotSupported —
V 2 G Comms Established CP_a073_v2gCommsEstablished —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of CP_a073.

Browse all CP alert codes