OCS1P_w124 — Cushion Self Open
Full alert identifier: OCS1P_w124_cushionSelfOpen
Alert description
The cushion self capacitance sensor is open
Potential impact
The classification cannot be performed
Set condition
The frequency reading is > 45kHz
Clear condition
The frequency reading returns below 45kHz
Signals to check
These diagnostic fields are associated with OCS1P_w124. Check the alert's Payload in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Cushion Self Freq
OCS1P_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of OCS1P_w124.