Alert description

PCS detects its sigma delta module has malfunctioned

Potential impact

Inability to precharge HV bus, inability to support 12V system, inability to drive

Set condition

DCDC sigma delta module detects clock fault

Clear condition

DCDC converter state machine clears faults

Signals to check

These diagnostic fields are associated with PCS_a039. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
SD Module Clock Fault HV PCS_a039_SDModuleClockFault_HV —
SD Module Clock Fault LV PCS_a039_SDModuleClockFault_LV —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PCS_a039.