PMF_a006 — Under Torque Check
Full alert identifier: PMF_a006_underTorqueCheck
Alert description
Pedal Monitor Warning: DI torque actual does not match PM torque measured
Potential impact
No immediate impact.
Set condition
Set when absolute difference between DIx_torqueActual and PMx_torqueMeasured is > 100Nm for 100ms
Clear condition
This alert will clear 1s after torque difference is below threshold
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PMF_a006.