Skip to content

PMR_a058 — Measured Hvil Current Frozen

Full alert identifier: PMR_a058_measuredHvilCurrentFrozen

Alert description

The Pedal Monitor (PM) detects that the measured high voltage interlock loop (HVIL) current is consistently an irrational value, which may affect PM functionality.

Potential impact

Vehicle functions that depend on PM HVIL statuses may be unavailable, or their performance may be affected. Other alerts may also be present as the high voltage (HV) battery contactors will be unable to close.

Set condition

The PM detects the measured HVIL current is consistently an irrational value for more than 60 seconds.

Clear condition

Clears when the PM no longer detects a consistent irrational HVIL current.

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PMR_a058.