PM_a038 — Inconsistent Torque Sign
Full alert identifier: PM_a038_inconsistentTorqueSign
Alert description
Pedal Monitor Warning: Master/Slave Torque Sign is Inconsistent.
Potential impact
The safety monitor will disable innhibit torque production for the remainder of the drive cycle.
Set condition
The safety monitor sets this condition torque production error is detected.
Clear condition
This alert will clear on the next drive cycle.
Signals to check
Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.
| Signal | Unit |
|---|---|
Master Torque
PM_
|
Nm |
Pedal Pos
PM_
|
% |
Slave Torque
PM_
|
Nm |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PM_a038.