RCM2_a275 — Imu Ptch R8 Off Comp Neg SLDC
Full alert identifier: RCM2_a275_imuPtchR8OffCompNegSLDC
Alert description
Drive Cycle IMU Pitch Rate Offset Compensation Maximum Negative Saturation Slow Learning Limit Reached
Potential impact
The inertial measurement offsets can no longer be learned during this drive cycle.
Set condition
The inertial measurement learned offset has reached the limit for this drive cycle.
Clear condition
Clears automatically on next drive cycle.
Signals to check
These diagnostic fields are associated with RCM2_a275. Check the alert's Payload in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Alert Log Error Code High
RCM2_
|
— |
Alert Log Error Code Low
RCM2_
|
— |
Imu Ptch R 8 Off Comp Neg SLDC S
RCM2_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of RCM2_a275.