Skip to content

RCM2_a317 — Imu Acc X Lg Mon Chl Temp

Full alert identifier: RCM2_a317_imuAccXLgMonChlTemp

Alert description

The low g longitudinal acceleration (Ax-Lg) has a temporary channel monitoring condition.

Potential impact

The safety restraint system may not perform as designed.

Set condition

The inertial measurement is temporarily unavailable.

Clear condition

Clears automatically.

Signals to check

These diagnostic fields are associated with RCM2_a317. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Alert Log Error Code High RCM2_a317_alertLogErrorCodeHigh —
Alert Log Error Code Low RCM2_a317_alertLogErrorCodeLow —
Imu Acc X Lg Mon Chl Temp S RCM2_a317_imuAccXLgMonChlTemp_s —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of RCM2_a317.

Browse all RCM2 alert codes