RCM2_a462 — Pres Ped Pro R Open
Full alert identifier: RCM2_a462_presPedProROpen
Message shown in the car
Pedestrian safety system issue - Service required Event data recording may be limited
Alert description
The right pedestrian protection impact pressure tube sensor has an open circuit.
Potential impact
The pedestrian safety system may not perform as designed.
Set condition
There is a condition with the right pedestrian protection sensor.
Clear condition
The condition is rectified.
Signals to check
These diagnostic fields are associated with RCM2_a462. Check the alert's Payload in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Alert Log Error Code High
RCM2_
|
— |
Alert Log Error Code Low
RCM2_
|
— |
Pres Ped Pro R Open S
RCM2_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of RCM2_a462.