Skip to content

RCM2_a471 — Up Frnt Ped Pro L Sht2 Bat

Full alert identifier: RCM2_a471_upFrntPedProLSht2Bat

Message shown in the car

Pedestrian safety system issue - Service required Event data recording may be limited

Alert description

The left pedestrian protection impact accelerometer (PCSL) has a short to battery.

Potential impact

The pedestrian safety system may not perform as designed.

Set condition

There is a short to battery with the left pedestrian protection impact sensor.

Clear condition

The short to battery is rectified.

Signals to check

These diagnostic fields are associated with RCM2_a471. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Alert Log Error Code High RCM2_a471_alertLogErrorCodeHigh —
Alert Log Error Code Low RCM2_a471_alertLogErrorCodeLow —
Up Frnt Ped Pro L Sht 2 Bat S RCM2_a471_upFrntPedProLSht2Bat_s —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of RCM2_a471.

Browse all RCM2 alert codes