Skip to content

SDCR_a001 — Power On Self Test Failed

Full alert identifier: SDCR_a001_powerOnSelfTestFailed

Message shown in the car

Powertrain requires service Vehicle speed and power may be limited

Alert description

The Secondary Disconnect Controller (SDC) did not pass the drive unit pyro self-test.

Potential impact

Pyro disconnect may not function as expected.

Set condition

Sets when Pyro test voltages are out of range during pyro self-test.

Clear condition

Clears after a power cycle when the pyro self-test completes successfully.

Signals to check

Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.

Signal Unit
HV Backup Supply V SDCR_a001_HVBackupSupplyV V
Boost Rail V SDCR_a001_boostRailV V
Expected Pyro V Max SDCR_a001_expectedPyroV_max V
Expected Pyro V Min SDCR_a001_expectedPyroV_min V
Pyro Sense V SDCR_a001_pyroSenseV V
Signal Unit
From State SDCR_a001_fromState
0
PENDING
1
TEST PYRO BOTH OFF1
2
TEST PYRO H ON
3
TEST PYRO BOTH OFF2
4
TEST PYRO L ON
5
PASSED
6
FAILED
7
SKIPPED
—

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of SDCR_a001.

Browse all SDCR alert codes