SDCR_a027 — Di CAN MIA

Full alert identifier: SDCR_a027_diCanMIA

Some fields retain information from an earlier alert reference.

Alert description

Drive inverter (DI) controller area network (CAN) communication to the secondary disconnect controller (SDC) is missing (MIA).

Potential impact

SDC is relying on universal asynchronous receiver-transmitter (UART) data from DI to assess DI presence.

Set condition

SDC is not receiving all expected CAN frames from DI.

Clear condition

SDC receives all expected CAN frames from DI.

Signals to check

These diagnostic fields are associated with SDCR_a027. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Lv State SDCR_a027_lvState —
Power SDCR_a027_power —
Timeout SDCR_a027_timeout —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of SDCR_a027.

Browse all SDCR alert codes