Skip to content

VCFRONT_a055 — T LVBMS Bmb Vref Bad

Full alert identifier: VCFRONT_a055_TLVBMS_BmbVrefBad

Historical alert: retained from an earlier reference.

Alert description

Indicates a Battery Monitoring Board (BMB) reference voltage has continuously been out of bounds

Potential impact

Other BMB voltage signals will be substituted given the reference voltage is unreliable

Set condition

Any BMB reference voltage has continuously deviated outside the in-bounds threshold of the nominal voltage

Clear condition

All BMB reference voltages continuously remain within the in-bounds threshold of the nominal voltage

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCFRONT_a055.

Browse all VCFRONT alert codes