VCFRONT_a253 — Max Chrge Sssion Tmeout

Full alert identifier: VCFRONT_a253_maxChrgeSssionTmeout

Alert description

The low voltage (LV) battery charge cycle was stopped before it reached either its Amp hour or current targets, as the maximum time period for a charging session timeout had been reached.

Potential impact

Increased energy drain when the vehicle is idle, which may cause lower than expected vehicle state of charge (SOC). LV battery may have lower charge than expected.

Set condition

The vehicle controller detects the maximum LV battery charging session timeout is reached.

Clear condition

The next LV battery charging session starts.

Signals to check

Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.

Signal Unit
IBS Amp Hours VCFRONT_a253_IBSAmpHours Ah
IBS Current VCFRONT_a253_IBSCurrent A
LV Battery Temp VCFRONT_a253_LVBatteryTemp
127
SNA
degC
Signal Unit
Amp Hour Target Not Reached VCFRONT_a253_ampHourTargetNotReached —
Current Not Tapered VCFRONT_a253_currentNotTapered —
First Charge OTA VCFRONT_a253_firstChargeOTA —
First Charge POR VCFRONT_a253_firstChargePOR —
Frunk Open VCFRONT_a253_frunkOpen —
Service Mode VCFRONT_a253_serviceMode —