Skip to content

BCS2C_w042 — Track Motor Logic Temp UV

Full alert identifier: BCS2C_w042_trackMotorLogicTempUV

Alert description

3930 Fault - Under voltage, Overtemperature, Incorrect Logic Levels

Potential impact

If overtemperature, A3930 will continue to drive. If undervoltage or logic fault, motor control will be disabled.

Set condition

Vreg < 8V, Overtemperature > 170 deg C on the A3930,Logic levels below lockout voltage level of 4V

Clear condition

Any of the following conditions go away: overtemperature, undervoltage, incorrect logic levels

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of BCS2C_w042.

Browse all BCS2C alert codes