BCS2L_w041 — Track Motor Low Current
Full alert identifier: BCS2L_w041_trackMotorLowCurrent
Alert description
3930 Fault - Low Load Current. Senses less than 500mV
Potential impact
Fault flag thrown, track motor will continue to work
Set condition
Track motor senses low current
Clear condition
The sense amplifier senses greater than 500mV
Signals to check
Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.
| Signal | Unit |
|---|---|
Track Motor Low Current
BCS2L_
|
A |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of BCS2L_w041.