Skip to content

BMS_f059 — SW Pack Voltage Sensing

Full alert identifier: BMS_f059_SW_Pack_Voltage_Sensing

Message shown in the car

Service is required PULL OVER SAFELY

Alert description

The battery management system (BMS) detects that the pack voltage does not match the sum of the brick voltages.

Potential impact

Inability to charge, drive, or support the low voltage (LV) system

Set condition

The BMS detects that the HV pack voltage differs from the sum of the brick voltages by more than 3%.

Clear condition

The BMS detects that the HV pack voltage is within 3% of the sum of the brick voltages.

Signals to check

Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.

Signal Unit
Pack Minus BMS_a059_packMinus V
Pack Plus BMS_a059_packPlus V
Pack Voltage BMS_a059_packVoltage
2047
SNA
V
Sum Of Brick V BMS_a059_sumOfBrickV V
Signal Unit
Pack V Error Type BMS_a059_packVErrorType
0
PACK DCLINK MISM
1
PACK BRICK MISM
2
PACK DR ANC MISM
3
PACK FC ANC MISM
4
VOLTAGE TOO HIGH
5
PACKPLUSMINUS
—

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of BMS_f059.

Browse all BMS alert codes