Skip to content

BMS_f072 — SW Unexpctd Ctr Bhvr

Full alert identifier: BMS_f072_SW_Unexpctd_Ctr_Bhvr

Alert description

The Battery Management System (BMS) detects the contactors took longer to pull in than expected, based on service disconnect voltage. There may be an issue with one of the battery contactors.

Potential impact

This information is not available in the alert reference.

Set condition

This information is not available in the alert reference.

Clear condition

This information is not available in the alert reference.

Signals to check

These diagnostic fields are associated with BMS_f072. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Ctr Err Type BMS_a072_ctrErrType
0
POS PULLIN TIME TOO LONG
1
NEG PULLIN TIME TOO LONG
—
Pull In Time BMS_a072_pullInTime —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of BMS_f072.

Browse all BMS alert codes