BMS_f095 — SW Fast Chg Regulation

Full alert identifier: BMS_f095_SW_FastChg_Regulation

Alert description

The Battery Management System (BMS) stopped DC charging because the maximum brick voltage within the High Voltage (HV) battery or charge current exceeded the target value for too long.

Potential impact

Charging is temporarily unavailable.

Set condition

While charging, the maximum brick voltage or charge current exceeded the target value for too long.

Clear condition

The BMS reports the brick voltage or charge current is less than the maximum target value and charging ends.

Signals to check

Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.

Signal Unit
Soc BMS_a095_SOC PCT
Pack Current BMS_a095_packCurrent A
Target Current BMS_a095_targetCurrent A
Signal Unit
CHG FC Cont OK To Be Closed BMS_a095_CHG_FCContOKToBeClosed —
CHG FC State BMS_a095_CHG_FCState —
CSI State BMS_a095_CSIState —
Contactor State BMS_a095_contactorState
0
OPEN
1
PRECHARGE
2
CLOSED
3
SNA
—
Contactor State FC BMS_a095_contactorStateFC
0
OPEN
1
PRECHARGE
2
CLOSED
3
SNA
—
Err Type BMS_a095_errType —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of BMS_f095.

Browse all BMS alert codes