Skip to content

BMS_f140 — SW Over Current Sense

Full alert identifier: BMS_f140_SW_OverCurrent_Sense

Message shown in the car

Service is required Schedule service

Alert description

The battery management system (BMS) has detected that there is a high voltage (HV) battery current sensor (shunt) error.

Potential impact

Inability to charge, drive, or support the low voltage (LV) system

Set condition

The BMS detects a HV battery current sensor (shunt) is unable to trip its over current fault line.

Clear condition

The BMS detects that the condition clears.

Signals to check

These diagnostic fields are associated with BMS_f140. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Counter Locked Up BMS_a140_counterLockedUp —
Counter MIA For Hard Reset BMS_a140_counterMIAForHardReset —
Hwoc Failure Type BMS_a140_hwocFailureType
0
FAILED EXPECTED PASS
1
PASSED EXPECTED FAIL
—

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of BMS_f140.

Browse all BMS alert codes