BMS_f150 — SW precharge too long
Full alert identifier: BMS_f150_SW_precharge_too_long
Message shown in the car
Vehicle may not restart Service is required
Alert description
The battery management system (BMS) detects that it is taking too long to reach the target precharge voltage and prevents packs contactors from closing. This indicates that the voltage on the DC link bus rose more slowly than expected.
Potential impact
Inability to charge, drive, or support the low voltage (LV) system
Set condition
The BMS detects that the voltage on the DC link bus is rising slower than it should be. Alert log signal data provides information on the specific condition(s) detected.
Clear condition
The BMS detects that the condition clears.
Signals to check
Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.
| Signal | Unit |
|---|---|
Coil Current
BMS_
|
A |
Dc Link V
BMS_
|
V |
Hvil V
BMS_
|
V |
Precharge Current
BMS_
|
A |
| Signal | Unit |
|---|---|
Ctr Set Failed
BMS_
|
— |
Err Type
BMS_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of BMS_f150.