Skip to content

BMS_w171 — SW Pack Motor Mismatch

Full alert identifier: BMS_w171_SW_Pack_Motor_Mismatch

Alert description

The battery management system (BMS) detects the GTW_frontDriveUnitType does not match the high voltage (HV) battery's expectations.

Potential impact

This alert is primarily informational and is used for logging purposes. It is usually triggered after an HV battery replacement.

Set condition

The BMS detects the GTW_frontDriveUnitType does not match the HV battery's expectations.

Clear condition

The GTW_frontDriveUnitType matches the HV battery's expectations.

Signals to check

These diagnostic fields are associated with BMS_w171. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Build Config ID BMS_a171_buildConfigID —
Front Drive Unit Type BMS_a171_frontDriveUnitType
0
SMALL OR NONE
1
PERMANENT MAGNET
—
Pack Hwid BMS_a171_packHwid —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of BMS_w171.

Browse all BMS alert codes