Skip to content

CHG_u005 — Prox Latched No Pilot

Full alert identifier: CHG_u005_proxLatchedNoPilot

Message shown in the car

Unable to charge - Charge station not powered Check power source or try a different station

Alert description

Pilot signal does not appear when the charge cable is plugged in. Typically indicates that the charge station does not have power. Customers should check the power source or move to a different station or stall.

Potential impact

This information is not available in the alert reference.

Set condition

This information is not available in the alert reference.

Clear condition

This information is not available in the alert reference.

Signals to check

These diagnostic fields are associated with CHG_u005. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Connector Latched CHG_u005_connectorLatched —
Pilot CHG_u005_pilot
0
NONE
1
FAULTED
2
LINE CHARGE
3
FAST CHARGE
4
IDLE
5
INVALID
6
UNUSED 6
7
SNA
—
Proximity CHG_u005_proximity
0
SNA
1
DISCONNECTED
2
UNLATCHED
3
LATCHED
—

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of CHG_u005.

Browse all CHG alert codes