CP_w086 — Dc Pin Temp Irrational
Full alert identifier: CP_w086_dcPinTempIrrational
Alert description
The charge port (CP) electronic control unit (ECU) detects an open circuit on the DC pin thermistor.
Potential impact
DC charging does not start.
Set condition
The CP ECU detects that the DC pin temperature is less than the open circuit threshold for more than 1 second.
Clear condition
The CP ECU detects that the DC pin temperature is greater than the open circuit threshold for more than 1 second.
Signals to check
Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.
| Signal | Unit |
|---|---|
Dc Pin Temp
CP_
|
C |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of CP_w086.