DI_f002 — Hw Phase Bgate Drive
Full alert identifier: DI_f002_hwPhaseBgateDrive
Message shown in the car
PULL OVER SAFELY Exiting and re-entering vehicle may restore operation
Alert description
Drive Inverter Fault: Phase B gate driver
Potential impact
This information is not available in the alert reference.
Set condition
This information is not available in the alert reference.
Clear condition
This information is not available in the alert reference.
Signals to check
These diagnostic fields are associated with DI_f002. Check the alert's Payload in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Asynch Stop H
DI_
|
— |
Asynch Stop L
DI_
|
— |
Deadtime Error H
DI_
|
— |
Deadtime Error L
DI_
|
— |
Desat H
DI_
|
— |
Desat L
DI_
|
— |
Gate Drive Err Counter
DI_
|
— |
Local Comm Error H
DI_
|
— |
Show 35 more fields
| Signal | Unit |
|---|---|
Local Comm Error L
DI_
|
— |
Local Reg Error H
DI_
|
— |
Local Reg Error L
DI_
|
— |
Local Reset H
DI_
|
— |
Local Reset L
DI_
|
— |
Overvolt VDD H
DI_
|
— |
Overvolt VDD L
DI_
|
— |
Overvolt VH H
DI_
|
— |
Overvolt VH L
DI_
|
— |
Overvolt VL H
DI_
|
— |
Overvolt VL L
DI_
|
— |
Remote Comm Error H
DI_
|
— |
Remote Comm Error L
DI_
|
— |
Remote Reg Error H
DI_
|
— |
Remote Reg Error L
DI_
|
— |
Remote Reset H
DI_
|
— |
Remote Reset L
DI_
|
— |
Selftest Desat H
DI_
|
— |
Selftest Desat L
DI_
|
— |
Sense H
DI_
|
— |
Sense L
DI_
|
— |
Spi Error H
DI_
|
— |
Spi Error L
DI_
|
— |
Thermal Shutdown H
DI_
|
— |
Thermal Shutdown L
DI_
|
— |
Thermal Warning H
DI_
|
— |
Thermal Warning L
DI_
|
— |
Undervolt VCC H
DI_
|
— |
Undervolt VCC L
DI_
|
— |
Undervolt VDD H
DI_
|
— |
Undervolt VDD L
DI_
|
— |
Undervolt VH H
DI_
|
— |
Undervolt VH L
DI_
|
— |
Undervolt VL H
DI_
|
— |
Undervolt VL L
DI_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of DI_f002.