Skip to content

DI_f016 — Safe State Applied

Full alert identifier: DI_f016_safeStateApplied

Message shown in the car

Unable to drive PULL OVER SAFELY

Alert description

Drive Inverter Fault: Power stage applied a safe state

Potential impact

This information is not available in the alert reference.

Set condition

This information is not available in the alert reference.

Clear condition

This information is not available in the alert reference.

Signals to check

These diagnostic fields are associated with DI_f016. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Asc Monitor DI_a016_ascMonitor —
Gate Drive Fault Line DI_a016_gateDriveFaultLine —
Motor RPM DI_a016_motorRPM RPM
New Safe State DI_a016_newSafeState
0
NONE
1
ALL OFF
2
3PS HIGH
3
3PS LOW
—
Old Safe State DI_a016_oldSafeState
0
NONE
1
ALL OFF
2
3PS HIGH
3
3PS LOW
—
Pedal Monitor Pre Watchdog DI_a016_pedalMonitorPreWatchdog —
Safety I Cfault Line DI_a016_safetyICfaultLine —
Torque Motor DI_a016_torqueMotor Nm
Show 1 more field
Signal Unit
Uncontrolled Regen Zone DI_a016_uncontrolledRegenZone —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of DI_f016.

Browse all DI alert codes