EFUSE_w158 — Air Comp Output Stuck On

Full alert identifier: EFUSE_w158_airCompOutputStuckOn

Alert description

Upstream VBAT_FUSED to deenergize air compressor.

Potential impact

Air suspension compressor disabled.

Set condition

Air compressor output detected to be on while being commanded off.

Clear condition

Vehicle power state cycle.

Signals to check

Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.

Signal Unit
Current EFUSE_a158_current A
Time Off EFUSE_a158_timeOff milliseconds
Voltage EFUSE_a158_voltage V

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of EFUSE_w158.