PLCRLY_a046 — Lost Comms EVSE

Full alert identifier: PLCRLY_a046_lostCommsEVSE

Alert description

Vehicle unexpectedly lost digital communications with offboard charging equipment. Charging may be interrupted.

Potential impact

Charging may be interrupted unexpectedly.

Set condition

Any message required to control a charge session via digital communications goes missing unexpectedly.

Clear condition

The Power Line Communication Relay (PLCRLY) electronic control unit (ECU) detects a valid line charge pilot signal, the charge cable is unplugged, or the charge port attempts to re-establish digital communications.

Signals to check

These diagnostic fields are associated with PLCRLY_a046. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
CC Chg Status Flag PLCRLY_a046_CC_chgStatus_flag —
FC Limits Flag PLCRLY_a046_FC_limits_flag —
FC Max Limits Flag PLCRLY_a046_FC_maxLimits_flag —
FC Status Flag PLCRLY_a046_FC_status_flag —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PLCRLY_a046.