PLCRLY_a046 — Lost Comms EVSE
Full alert identifier: PLCRLY_a046_lostCommsEVSE
Alert description
Vehicle unexpectedly lost digital communications with offboard charging equipment. Charging may be interrupted.
Potential impact
Charging may be interrupted unexpectedly.
Set condition
Any message required to control a charge session via digital communications goes missing unexpectedly.
Clear condition
The Power Line Communication Relay (PLCRLY) electronic control unit (ECU) detects a valid line charge pilot signal, the charge cable is unplugged, or the charge port attempts to re-establish digital communications.
Signals to check
These diagnostic fields are associated with PLCRLY_a046. Check the alert's Payload in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
CC Chg Status Flag
PLCRLY_
|
— |
FC Limits Flag
PLCRLY_
|
— |
FC Max Limits Flag
PLCRLY_
|
— |
FC Status Flag
PLCRLY_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PLCRLY_a046.