PLCRLY_a066 — Prox Latched Idle Pilot
Full alert identifier: PLCRLY_a066_proxLatchedIdlePilot
Alert description
The Power Line Communication Relay (PLCRLY) detects the control pilot signal remains in state B1, indicating the charge station is connected to the vehicle but is not ready to charge the vehicle, for too long while a charge cable is plugged into the Charge Port (CP).
Potential impact
Charging may not start or may be interrupted unexpectedly.
Set condition
PLCRLY detects charge handle proximity as connected to the CP without pressing the charge handle button, and control pilot signal is detected in state B1 for more than five seconds.
Clear condition
Charge handle proximity is no longer detected as connected to the CP without charge handle button pressed, or control pilot signal is no longer detected in state B1. Clears after five seconds if either of these conditions is true and a charge cable is still present.
Signals to check
Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.
| Signal | Unit |
|---|---|
Pilot High
PLCRLY_
|
V |
Pilot Low
PLCRLY_
|
V |
| Signal | Unit |
|---|---|
Proximity
PLCRLY_
|
— |
Check other alerts