Skip to content

PLCRLY_a072 — V2g Evcc Timeout

Full alert identifier: PLCRLY_a072_v2gEvccTimeout

Alert description

The Power Line Communication Relay (PLCRLY) electronic control unit (ECU) detects that the charging session is taking longer to startup than expected and exceeds the maximum time frame.

Potential impact

CCS charging may not start or may be interrupted.

Set condition

The charging session does not start within the expected time frame.

Clear condition

The charge cable is removed or communication with the EVSE stops.

Signals to check

These diagnostic fields are associated with PLCRLY_a072. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Cable Check Expired PLCRLY_a072_cableCheckExpired —
Comms Setup Expired PLCRLY_a072_commsSetupExpired —
Current Message PLCRLY_a072_currentMessage —
Pre Charge Expired PLCRLY_a072_preChargeExpired —
Ready To Charge Expired PLCRLY_a072_readyToChargeExpired —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PLCRLY_a072.

Browse all PLCRLY alert codes