PLCRLY_a089 — Plc Config Mismatch
Full alert identifier: PLCRLY_a089_plcConfigMismatch
Alert description
The GTW configuration for PLC support does not match the hardware installed in the vehicle
Potential impact
The GTW will not update the PLC modem and PIB during OTA updates
Set condition
Configuration of the GTW PLC support type does not match the Charge Port configuration
Clear condition
Configuration of the GTW PLC support type matches the Charge Port configuration
Signals to check
These diagnostic fields are associated with PLCRLY_a089. Check the alert's Payload in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Gtw Plc Support Type
PLCRLY_
|
— |
Plc Modem Populated
PLCRLY_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PLCRLY_a089.