Skip to content

PLCRLY_a089 — Plc Config Mismatch

Full alert identifier: PLCRLY_a089_plcConfigMismatch

Alert description

The GTW configuration for PLC support does not match the hardware installed in the vehicle

Potential impact

The GTW will not update the PLC modem and PIB during OTA updates

Set condition

Configuration of the GTW PLC support type does not match the Charge Port configuration

Clear condition

Configuration of the GTW PLC support type matches the Charge Port configuration

Signals to check

These diagnostic fields are associated with PLCRLY_a089. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Gtw Plc Support Type PLCRLY_a089_gtwPlcSupportType
0
NONE
1
GEN3 EU CP
2
NATIVE CHARGE PORT
—
Plc Modem Populated PLCRLY_a089_plcModemPopulated —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PLCRLY_a089.

Browse all PLCRLY alert codes