Skip to content

PLCRLY_a118 — Iec Combo Lock Up

Full alert identifier: PLCRLY_a118_iecComboLockUp

Alert description

Charge port detected a CCS lockup

Potential impact

This information is not available in the alert reference.

Set condition

This information is not available in the alert reference.

Clear condition

This information is not available in the alert reference.

Signals to check

These diagnostic fields are associated with PLCRLY_a118. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Cable Connected PLCRLY_a118_cableConnected —
Evcc State PLCRLY_a118_evccState
0
INIT
1
WAIT FOR HANDSHAKE
2
COMMS ESTABLISHED
3
COMMS TIMEOUT
4
COMMS SHUTDOWN
5
COMMS PAUSED
6
COMMS FAULT
7
STATE COUNT
—
Evcc Task Mia Time PLCRLY_a118_evccTaskMiaTime ms
Sdp State PLCRLY_a118_sdpState
0
INIT
1
ACTIVE
2
SUCCESS
3
SIDE CHANNEL REQUESTS
4
SIDE CHANNEL REQUESTS DONE
5
FAULT
—
Sdp Task Mia Time PLCRLY_a118_sdpTaskMiaTime ms
Slac State PLCRLY_a118_slacState —
Tcp Ip Task Mia Time PLCRLY_a118_tcpIpTaskMiaTime ms
Tesla V 2 G State PLCRLY_a118_teslaV2gState
0
INIT
1
WAIT FOR COMMS
2
COMMS ESTABLISHED
3
COMMS SHUTDOWN
4
COMMS TIMEOUT
—
Show 3 more fields
Signal Unit
Tesla V 2 G Task Mia Time PLCRLY_a118_teslaV2gTaskMiaTime ms
V 2 G State PLCRLY_a118_v2gState
0
INIT
1
IDLE
2
SDP
3
CONNECT TCP
—
V 2 G Task Mia Time PLCRLY_a118_v2gTaskMiaTime ms

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PLCRLY_a118.

Browse all PLCRLY alert codes