Skip to content

PLCRLY_a135 — Sdp Attempts Failed

Full alert identifier: PLCRLY_a135_sdpAttemptsFailed

Message shown in the car

Charging equipment communication error Unplug via Mobile App or Touchscreen and retry

Alert description

Charging session not started due to communication failures during the EVSE discovery protocol (SDP) which occurs during CCS charging

Potential impact

Charging may not start

Set condition

The SDP failed an unexpected amount of time

Clear condition

Cleared when the cable is disconnected or if an SDP attempt succeeded

Signals to check

These diagnostic fields are associated with PLCRLY_a135. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Evse Attenuation PLCRLY_a135_evseAttenuation —
Pilot State PLCRLY_a135_pilotState
0
NONE
1
FAULTED
2
LINE CHARGE
3
FAST CHARGE
4
IDLE
5
INVALID
6
UNUSED 6
7
SNA
—
Sdp Err PLCRLY_a135_sdpErr
0
ERR NONE
1
ERR INVALID ARG
2
ERR NO RX DATA
3
ERR INVALID DATA
4
NUM OF ERRS
—

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PLCRLY_a135.

Browse all PLCRLY alert codes