Set Thermal components to target positions for one minute or sweep them twice between end points. The routine will complete when all components have reached their target positions. Until then, other components will remain at their target positions or continue sweeping. Unselected components will default to a target position that minimizes noise, vibration, and harshness (NVH).
Select your vehicle’s hardware to see task details, requirements, and inputs. Availability is confirmed after connection.
Actuators are moved and motors are enabled during this routine, ensure components are not blocked or broken.
sweep_louver · Bool
Actuates the louver from open to close, and back. (2x)
Default: false
set_target_louver · Int
Set louver intake position (0:Closed 100:Open) (-1 not specified)
Default: -1
sweep_radiator_fan · Bool
Ramps up the radiator fan from minimum to maximum, and back. (2x)
Default: false
set_target_radiator_fan · Int
Set target RPM (850:Min 2500:Max) (-1 not specified)
Default: -1
sweep_blower · Bool
Ramps up the blower from minimum to maximum, and back. (2x)
Default: false
set_target_blower · Int
Set target RPM (950:Min 3500:Max) (-1 not specified)
Default: -1
sweep_batt_pump · Bool
Ramps up the battery pump from minimum to maximum, and back. (2x)
Default: false
set_target_batt_pump · Int
Set target RPM (1700:Min 6000:Max) (-1 not specified)
Default: -1
sweep_pt_pump · Bool
Ramps up the Powertrain pump from minimum to maximum, and back. (2x)
Default: false
set_target_pt_pump · Int
Set target RPM (1700:Min 6000:Max) (-1 not specified)
Default: -1
Actuators are moved and motors are enabled during this routine, ensure components are not blocked or broken.
sweep_louver · Bool
Actuates the louver from open to close, and back. (2x)
Default: false
set_target_louver · Int
Set louver intake position (0:Closed 100:Open) (-1 not specified)
Default: -1
sweep_radiator_fan · Bool
Ramps up the radiator fan from minimum to maximum, and back. (2x)
Default: false
set_target_radiator_fan · Int
Set target RPM (850:Min 2500:Max) (-1 not specified)
Default: -1
sweep_blower · Bool
Ramps up the blower from minimum to maximum, and back. (2x)
Default: false
set_target_blower · Int
Set target RPM (950:Min 3500:Max) (-1 not specified)
Default: -1
sweep_batt_pump · Bool
Ramps up the battery pump from minimum to maximum, and back. (2x)
Default: false
set_target_batt_pump · Int
Set target RPM (1700:Min 6000:Max) (-1 not specified)
Default: -1
sweep_pt_pump · Bool
Ramps up the Powertrain pump from minimum to maximum, and back. (2x)
Default: false
set_target_pt_pump · Int
Set target RPM (1700:Min 6000:Max) (-1 not specified)
Default: -1
Move all windows to a specified position.
PROC_VC_X_ALL-COMMAND-WINDOW-POSITION
Tests connection and harness of both left and right blind spot indicator lights.
TEST-SELF_VC_X_BLIND-SPOT-LED
Runs blower identification first, then runs the HVAC system performance test.
TEST_VC_X_HVAC-BLOWER-IDENTIFICATION-AND-HVAC-PERFORMANCE
Query the current power-off status for a specific component. Returns the status and remaining timeout for any active power-off request.
PROC_VC_X_STATUS-POWER-OFF-REQUEST