Skip to content

HVP_w013 — Bmb Communication

Full alert identifier: HVP_w013_BmbCommunication

Alert description

The High Voltage Processor (HVP) detects a communication interruption in the Battery Monitoring Board (BMB) chain.

Potential impact

There may be a loss of BMB sensor data.

Set condition

The HVP detects a communication interruption with the BMB daisy chain.

Clear condition

No communication interruptions with the BMB daisy chain are detected.

Signals to check

These diagnostic fields are associated with HVP_w013. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Bmb Chain Break Type HVP_a013_bmbChainBreakType
0
NONE
1
SINGLE BREAK
2
DOUBLE BREAK
3
INVALID BREAK
4
HEAD BREAK
5
TAIL BREAK
—
Bmb Comm Status Type A HVP_a013_bmbCommStatusTypeA
0
MISSING
1
BAD
2
NOMINAL
3
BYPASSED
—
Bmb Comm Status Type B HVP_a013_bmbCommStatusTypeB
0
MISSING
1
BAD
2
NOMINAL
3
BYPASSED
—
Break Location A HVP_a013_breakLocationA —
Break Location B HVP_a013_breakLocationB —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of HVP_w013.

Browse all HVP alert codes