Skip to content

HVP_w058 — Bmb Vref Bad

Full alert identifier: HVP_w058_BmbVrefBad

Alert description

The High Voltage Processor (HVP) detects that one or more Battery Monitoring Board (BMB) reference voltages are continuously out of bounds.

Potential impact

BMB voltage signals will be substituted.

Set condition

One or more BMB reference voltages are continuously outside the in-bounds threshold of the nominal voltage.

Clear condition

All BMB reference voltages continuously remain within the in-bounds threshold of the nominal voltage.

Signals to check

Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.

Signal Unit
Vref Sample HVP_a058_VrefSample V
Signal Unit
Vref Status HVP_a058_VrefStatus
0
MISSING
1
BAD
2
NOMINAL
3
BYPASSED
—
Vref Type HVP_a058_VrefType
0
V5
1
V3
2
REF2
—
Bmb Device Id HVP_a058_bmbDeviceId —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of HVP_w058.

Browse all HVP alert codes