Skip to content

PCS_a069 — Chg Pfc Line Didt

Full alert identifier: PCS_a069_chgPfcLineDidt

Some fields retain information from an earlier alert reference.

Alert description

The onboard charger AC input current measurement changed too much between switching cycles compared to acceptable range, causing reduced AC charge rate. This alert indicates an unexpected, sudden drop or spike in the measured current has occurred, and it is frequently associated with a condition affecting the supply current from the AC grid.

Potential impact

Reduced AC charge rate.

Set condition

The onboard charger AC input current changed too much between switching cycles compared to acceptable range.

Clear condition

The onboard charger will restart the affected converter automatically until the maximum number of retry attempts has been reached.

Signals to check

These diagnostic fields are associated with PCS_a069. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Input Frequency PCS_a069_inputFrequency —
Input I Delta PCS_a069_inputIDelta —
Input Vrms PCS_a069_inputVrms —
Int Bus V PCS_a069_intBusV —
Ph State PCS_a069_phState —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PCS_a069.

Browse all PCS alert codes