PCS_a070 — Chg Pfc Line Dvdt

Full alert identifier: PCS_a070_chgPfcLineDvdt

Some fields retain information from an earlier alert reference.

Alert description

The onboard charger input voltage measurement changed too much between switching cycles compared to acceptable range, causing reduced AC charge rate. This alert indicates an unexpected and sudden drop or spike in the measured voltage has occurred, and it is frequently associated with a condition affecting the supply voltage from the AC grid.

Potential impact

Reduced AC charge rate.

Set condition

The onboard charger AC input voltage changed too much between switching cycles compared to acceptable range.

Clear condition

The onboard charger will restart the affected converter(s) automatically until the maximum number of retry attempts has been reached.

Signals to check

These diagnostic fields are associated with PCS_a070. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Input Frequency PCS_a070_inputFrequency —
Input V Delta PCS_a070_inputVDelta —
Input Vrms PCS_a070_inputVrms —
Int Bus V PCS_a070_intBusV —
Ph State PCS_a070_phState —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PCS_a070.