Skip to content

SDCR_a007 — Fault Currents Detected

Full alert identifier: SDCR_a007_faultCurrentsDetected

Alert description

Secondary Disconnect Controller (SDC) detected abnormal motor currents.

Potential impact

SDC may trigger the pyro disconnect.

Set condition

Sets when abnormal drive unit currents are detected by the SDC while Drive Inverter (DI) is not switching.

Clear condition

Clears when drive unit can control currents rationally or SDC processor is reset.

Signals to check

Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.

Signal Unit
Avg Ia SDCR_a007_avgIa A
Avg Ib SDCR_a007_avgIb A
Max Abs Currents SDCR_a007_maxAbsCurrents A
Max Abs Elc Speed SDCR_a007_maxAbsElcSpeed Hz
Signal Unit
Fault Reason Fault Currents At Speed SDCR_a007_faultReason_faultCurrentsAtSpeed —
Fault Reason Propagating 3 PS SDCR_a007_faultReason_propagating3PS —
Fault Reason Unmitigated UCR SDCR_a007_faultReason_unmitigatedUCR —
Imbalance Seen SDCR_a007_imbalanceSeen —
Phase Voltage Present SDCR_a007_phaseVoltagePresent —
Speed From Voltage SDCR_a007_speedFromVoltage —
Speed Was Valid SDCR_a007_speedWasValid —
Transient Handling SDCR_a007_transientHandling
0
ALL SKIPPED
1
SKIPPED 3PS
2
3PS EARLY EXIT
3
3PS WAITED
—
Show 1 more field
Signal Unit
Ucr Seen SDCR_a007_ucrSeen —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of SDCR_a007.

Browse all SDCR alert codes