SDCR_a007 — Fault Currents Detected
Full alert identifier: SDCR_a007_faultCurrentsDetected
Alert description
Secondary Disconnect Controller (SDC) detected abnormal motor currents.
Potential impact
SDC may trigger the pyro disconnect.
Set condition
Sets when abnormal drive unit currents are detected by the SDC while Drive Inverter (DI) is not switching.
Clear condition
Clears when drive unit can control currents rationally or SDC processor is reset.
Signals to check
Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.
| Signal | Unit |
|---|---|
Avg Ia
SDCR_
|
A |
Avg Ib
SDCR_
|
A |
Max Abs Currents
SDCR_
|
A |
Max Abs Elc Speed
SDCR_
|
Hz |
| Signal | Unit |
|---|---|
Fault Reason Fault Currents At Speed
SDCR_
|
— |
Fault Reason Propagating 3 PS
SDCR_
|
— |
Fault Reason Unmitigated UCR
SDCR_
|
— |
Imbalance Seen
SDCR_
|
— |
Phase Voltage Present
SDCR_
|
— |
Speed From Voltage
SDCR_
|
— |
Speed Was Valid
SDCR_
|
— |
Transient Handling
SDCR_
|
— |
Show 1 more field
| Signal | Unit |
|---|---|
Ucr Seen
SDCR_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of SDCR_a007.