SDCR_a019 — Historical Fault Currents
Full alert identifier: SDCR_a019_historicalFaultCurrents
Alert description
Secondary Disconnect Controller (SDC) detected abnormal electrical currents during a previous power-ON state. Data retrieved from Electrically Erasable Programmable Read-Only Memory (EEPROM).
Potential impact
Drive unit may not be functional due to previous electrical condition.
Set condition
Sets when SDC detects abnormal electrical currents while Drive Inverter (DI) is not switching as expected during a previous power cycle.
Clear condition
Clears when SDC completes successful power-ON self-test.
Signals to check
Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.
| Signal | Unit |
|---|---|
Avg Ia
SDCR_
|
A |
Avg Ib
SDCR_
|
A |
Max Abs Currents
SDCR_
|
A |
Max Abs Elc Speed
SDCR_
|
Hz |
| Signal | Unit |
|---|---|
Fault Reason Fault Currents At Speed
SDCR_
|
— |
Fault Reason Propagating 3 PS
SDCR_
|
— |
Fault Reason Unmitigated UCR
SDCR_
|
— |
Imbalance Seen
SDCR_
|
— |
Phase Voltage Present
SDCR_
|
— |
Speed From Voltage
SDCR_
|
— |
Speed Was Valid
SDCR_
|
— |
Transient Handling
SDCR_
|
— |
Show 1 more field
| Signal | Unit |
|---|---|
Ucr Seen
SDCR_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of SDCR_a019.