Skip to content

VCRIGHT_a263 — Seat Track Stall Debug

Full alert identifier: VCRIGHT_a263_seatTrackStallDebug

Some fields retain information from an earlier alert reference.

Alert description

The seat track motor has unexpectedly stalled.

Potential impact

Motor will recalibrate if the stall is in an expected region, do nothing otherwise.

Set condition

Current draw exceeds stall limit.

Clear condition

The motor is not in a movement state. It may also be in a movement state, but has not detected a stall.

Signals to check

These diagnostic fields are associated with VCRIGHT_a263. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Seat Motor Current VCRIGHT_a263_seatMotorCurrent —
Seat Motor D Current VCRIGHT_a263_seatMotorDCurrent —
Seat Motor Pos Real VCRIGHT_a263_seatMotorPosReal —
Seat Motor State VCRIGHT_a263_seatMotorState —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCRIGHT_a263.

Browse all VCRIGHT alert codes