VCRIGHT_a265 — Seat Tilt Stall Debug
Full alert identifier: VCRIGHT_a265_seatTiltStallDebug
Some fields retain information from an earlier alert reference.
Alert description
The seat tilt motor has unexpectedly stalled.
Potential impact
Motor will recalibrate if the stall is in an expected region, do nothing otherwise.
Set condition
Current draw exceeds stall limit.
Clear condition
The seat tilt motor is not in a movement state. It may also be in a movement state, but has not detected a stall.
Signals to check
These diagnostic fields are associated with VCRIGHT_a265. Check the alert's Payload in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Seat Motor Current
VCRIGHT_
|
— |
Seat Motor D Current
VCRIGHT_
|
— |
Seat Motor Pos Real
VCRIGHT_
|
— |
Seat Motor State
VCRIGHT_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCRIGHT_a265.