Skip to content

BMS_f008 — HW HVIL

Full alert identifier: BMS_f008_HW_HVIL

Message shown in the car

Vehicle may not restart Service is required

Alert description

There is a hardware problem with the high voltage interlock loop (HVIL).

Potential impact

Inability to charge, drive, or support the low voltage (LV) system

Set condition

The complex programmable logic device (CPLD) has detected that the HVIL is open and the vehicle is not in Drive.

Clear condition

The CPLD detects that the condition clears.

Signals to check

Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.

Signal Unit
Contactor V BMS_a008_contactorV V
Hvil V BMS_a008_hvilV V
Serv Disc V BMS_a008_servDiscV V
Vehicle 12 V BMS_a008_vehicle12V V
Signal Unit
CPLD B 22 Hvil Fault BMS_a008_CPLD_b22_hvilFault —
CPLD B 41 Blind Mate Fault BMS_a008_CPLD_b41_blindMateFault —
CPLD B 47 Hvil Bad BMS_a008_CPLD_b47_hvilBad —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of BMS_f008.

Browse all BMS alert codes