BMS_f011 — HW Illegal Ctr Req
Full alert identifier: BMS_f011_HW_Illegal_Ctr_Req
Message shown in the car
Unable to start vehicle Service is required
Alert description
The battery management system (BMS) detects that there are system faults and prevents the pack contactors from closing.
Potential impact
Inability to charge, drive, or support the low voltage (LV) system
Set condition
The complex programmable logic device (CPLD) detects a condition that prevents pack contactors from closing. Alert log signal data provides information on the specific condition(s) detected
Clear condition
The CPLD detects that the condition clears.
Signals to check
These diagnostic fields are associated with BMS_f011. Check the alert's Payload in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Blind Mate Fault
BMS_
|
— |
Bmb Fault
BMS_
|
— |
Bmb Fault Diag Down
BMS_
|
— |
Bmb Fault Diag Up
BMS_
|
— |
Cont Hold
BMS_
|
— |
Cont Hold Timeout
BMS_
|
— |
Cont Safety Override
BMS_
|
— |
Contactor Power Req
BMS_
|
— |
Show 21 more fields
| Signal | Unit |
|---|---|
Contactor Prw Seq Err
BMS_
|
— |
Contactor State
BMS_
|
— |
Contactors On
BMS_
|
— |
Crc Error
BMS_
|
— |
Fast Kill Activated
BMS_
|
— |
Fch Cont Pwr Ovr Current
BMS_
|
— |
Fch Power On
BMS_
|
— |
Hvil Bad
BMS_
|
— |
Hvil Fault
BMS_
|
— |
Illegal Cont Req
BMS_
|
— |
Illegal Sleep Req
BMS_
|
— |
Key On
BMS_
|
— |
Mcs Over Current
BMS_
|
— |
Over Current
BMS_
|
— |
Over Current Diag
BMS_
|
— |
Over Voltage
BMS_
|
— |
Over Voltage Diag
BMS_
|
— |
Precharge OK
BMS_
|
— |
Sleep Timer Cal
BMS_
|
— |
Timer Alarm
BMS_
|
— |
Veh Can Bus Active
BMS_
|
— |
Check other alerts