BMS_f021 — SW Dr Limits Regulation
Full alert identifier: BMS_f021_SW_Dr_Limits_Regulation
Alert description
The battery management system (BMS) limits power because the pack current, pack voltage, or brick voltage, is outside of the expected bounds.
Potential impact
Inability to charge, drive, or support the low voltage (LV) system
Set condition
The BMS detects that regen current, discharge current, pack voltage, or brick voltage is too high or too low. Alert log signal data provides information on the specific condition(s) detected.
Clear condition
The BMS detects that the condition clears.
Signals to check
Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.
| Signal | Unit |
|---|---|
Brick V
BMS_
|
V |
Current Limit
BMS_
|
A |
Pack Current
BMS_
|
A |
Pack Voltage
BMS_
|
V |
Voltage Limit
BMS_
|
V |
| Signal | Unit |
|---|---|
Reg Err Type
BMS_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of BMS_f021.