BMS_f035 — SW Isolation

Full alert identifier: BMS_f035_SW_Isolation

Message shown in the car

Vehicle may not restart Service is required

Alert description

There is an external or internal isolation alert while pack contactors are closed.

Potential impact

Inability to charge, drive, or support the low voltage (LV) system

Set condition

The BMS detects that isolation is below the minimum threshold while contactors are closed.

Clear condition

Isolation restores to the nominal threshold.

Signals to check

Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.

Signal Unit
Iso R BMS_a035_isoR
255
SNA
kOhm
Max Brick T BMS_a035_maxBrickT C
Min Brick T BMS_a035_minBrickT C
Signal Unit
Iso Err Type BMS_a035_isoErrType
0
NONE
1
INTERNAL
2
EXTERNAL
3
EXT ANC
4
EXT DR
5
INTERNAL LATCHED
—
State BMS_a035_state —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of BMS_f035.

Browse all BMS alert codes