Skip to content

BMS_f151 — SW external isolation

Full alert identifier: BMS_f151_SW_external_isolation

Message shown in the car

Unable to start vehicle Service is required

Alert description

The battery management system (BMS) has detected that high voltage (HV) isolation is too low while pack contactors are closed.

Potential impact

Inability to charge, drive, or support the low voltage (LV) system

Set condition

The BMS detects that HV isolation is below the warning threshold while contactors are closed.

Clear condition

The BMS detects that the condition clears.

Signals to check

Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.

Signal Unit
Iso R BMS_a151_isoR
255
SNA
kOhm
Max Brick T BMS_a151_maxBrickT C
Min Brick T BMS_a151_minBrickT C
Signal Unit
Iso Err Type BMS_a151_isoErrType
0
NONE
1
INTERNAL
2
EXTERNAL
3
EXT ANC
4
EXT DR
5
INTERNAL LATCHED
—
State BMS_a151_state —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of BMS_f151.

Browse all BMS alert codes