BMS_f062 — SW Ctr Pwr Supply
Full alert identifier: BMS_f062_SW_Ctr_Pwr_Supply
Message shown in the car
Service is required PULL OVER SAFELY
Alert description
The battery management system (BMS) has detected that a pack contactor is not getting enough power.
Potential impact
Inability to charge, drive, or support the low voltage (LV) system
Set condition
The BMS detects that a pack contactor input voltage dropped below the limit threshold.
Clear condition
The BMS detects that both pack contactor input voltages are above the limit threshold.
Signals to check
Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.
| Signal | Unit |
|---|---|
Ctr Pwr V
BMS_
|
V |
Hv Disc V
BMS_
|
V |
| Signal | Unit |
|---|---|
Ctr Pwr Err Type
BMS_
|
— |
Check other alerts