Skip to content

BMS_f062 — SW Ctr Pwr Supply

Full alert identifier: BMS_f062_SW_Ctr_Pwr_Supply

Message shown in the car

Service is required PULL OVER SAFELY

Alert description

The battery management system (BMS) has detected that a pack contactor is not getting enough power.

Potential impact

Inability to charge, drive, or support the low voltage (LV) system

Set condition

The BMS detects that a pack contactor input voltage dropped below the limit threshold.

Clear condition

The BMS detects that both pack contactor input voltages are above the limit threshold.

Signals to check

Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.

Signal Unit
Ctr Pwr V BMS_a062_ctrPwrV V
Hv Disc V BMS_a062_hvDiscV V
Signal Unit
Ctr Pwr Err Type BMS_a062_ctrPwrErrType
0
LOW IN PRECHG
1
LOW IN ENABLE
2
CRASH IN ENABLE
3
CRASH IN PRECHG
—